bson/testdata/retryable-writes/legacy/bulkWrite-serverErrors.json
2025-03-17 20:58:26 +01:00

274 lines
5.6 KiB
JSON

{
"runOn": [
{
"minServerVersion": "4.0",
"topology": [
"replicaset"
]
},
{
"minServerVersion": "4.1.7",
"topology": [
"sharded",
"load-balanced"
]
}
],
"data": [
{
"_id": 1,
"x": 11
},
{
"_id": 2,
"x": 22
}
],
"tests": [
{
"description": "BulkWrite succeeds after PrimarySteppedDown",
"failPoint": {
"configureFailPoint": "failCommand",
"mode": {
"times": 1
},
"data": {
"failCommands": [
"update"
],
"errorCode": 189,
"errorLabels": [
"RetryableWriteError"
]
}
},
"operation": {
"name": "bulkWrite",
"arguments": {
"requests": [
{
"name": "deleteOne",
"arguments": {
"filter": {
"_id": 1
}
}
},
{
"name": "insertOne",
"arguments": {
"document": {
"_id": 3,
"x": 33
}
}
},
{
"name": "updateOne",
"arguments": {
"filter": {
"_id": 2
},
"update": {
"$inc": {
"x": 1
}
}
}
}
],
"options": {
"ordered": true
}
}
},
"outcome": {
"result": {
"deletedCount": 1,
"insertedCount": 1,
"insertedIds": {
"1": 3
},
"matchedCount": 1,
"modifiedCount": 1,
"upsertedCount": 0,
"upsertedIds": {}
},
"collection": {
"data": [
{
"_id": 2,
"x": 23
},
{
"_id": 3,
"x": 33
}
]
}
}
},
{
"description": "BulkWrite succeeds after WriteConcernError ShutdownInProgress",
"failPoint": {
"configureFailPoint": "failCommand",
"mode": {
"times": 1
},
"data": {
"failCommands": [
"insert"
],
"writeConcernError": {
"code": 91,
"errmsg": "Replication is being shut down",
"errorLabels": [
"RetryableWriteError"
]
}
}
},
"operation": {
"name": "bulkWrite",
"arguments": {
"requests": [
{
"name": "deleteOne",
"arguments": {
"filter": {
"_id": 1
}
}
},
{
"name": "insertOne",
"arguments": {
"document": {
"_id": 3,
"x": 33
}
}
},
{
"name": "updateOne",
"arguments": {
"filter": {
"_id": 2
},
"update": {
"$inc": {
"x": 1
}
}
}
}
],
"options": {
"ordered": true
}
}
},
"outcome": {
"result": {
"deletedCount": 1,
"insertedCount": 1,
"insertedIds": {
"1": 3
},
"matchedCount": 1,
"modifiedCount": 1,
"upsertedCount": 0,
"upsertedIds": {}
},
"collection": {
"data": [
{
"_id": 2,
"x": 23
},
{
"_id": 3,
"x": 33
}
]
}
}
},
{
"description": "BulkWrite fails with a RetryableWriteError label after two connection failures",
"failPoint": {
"configureFailPoint": "failCommand",
"mode": {
"times": 2
},
"data": {
"failCommands": [
"update"
],
"closeConnection": true
}
},
"operation": {
"name": "bulkWrite",
"arguments": {
"requests": [
{
"name": "deleteOne",
"arguments": {
"filter": {
"_id": 1
}
}
},
{
"name": "insertOne",
"arguments": {
"document": {
"_id": 3,
"x": 33
}
}
},
{
"name": "updateOne",
"arguments": {
"filter": {
"_id": 2
},
"update": {
"$inc": {
"x": 1
}
}
}
}
],
"options": {
"ordered": true
}
}
},
"outcome": {
"error": true,
"result": {
"errorLabelsContain": [
"RetryableWriteError"
]
},
"collection": {
"data": [
{
"_id": 2,
"x": 22
},
{
"_id": 3,
"x": 33
}
]
}
}
}
]
}